At Luan Solar, we specialize in delivering high-power output Topcon solar panels designed for maximum efficiency and long-term energy savings. Our advanced N-Type Topcon technology ensures higher energy conversion rates, lower degradation, and superior performance even in low-light conditions—making them the perfect choice for commercial and industrial solar projects.
The ZHU JKL132-D series is a 605–625W N-type bifacial TOPCon solar panel designed for utility-scale and large commercial PV systems. Combining 132 half cells, dual-glass construction and up to 23.13% front-side module efficiency, it delivers high energy output while maintaining a 1134 mm module width and approximately 34 kg weight. The module is suitable for projects that require high power density, bifacial energy generation, reliable mechanical performance and compatibility with common mounting and electrical system designs.
Why Choose Luan Solar?
Industry-Leading Efficiency – Our Topcon solar panels achieve higher energy yields, reducing your LCOE (Levelized Cost of Electricity).
Reliable & Durable – Built with premium materials, our panels are weather-resistant, PID-free, and backed by a strong warranty.
Custom Solutions for Businesses – Whether you need solar panels for large-scale solar farms, industrial facilities, or rooftop installations, we provide tailor-made energy solutions.
Global Expertise & Support – With years of experience in solar manufacturing and a proven track record of global projects, Luan Solar is your trusted partner in sustainable energy.
Quality Assurance
Power guarantee
Annual decay
A 605–625W bifacial TOPCon module offers a practical balance between high power output, system compatibility and project handling requirements. With a module width of 1134 mm and a weight of approximately 34 kg, the JKL132-D series can be integrated into many utility-scale and large commercial PV designs without moving into an extra-wide module format. Its high front-side efficiency reduces the module area required for a target capacity, while the bifacial dual-glass structure captures reflected irradiance from the rear side. The result is a module suited to projects that need strong energy yield, efficient transportation and manageable installation requirements rather than maximum wattage alone.
| Selection Factor | 605–625W Series | 700–720W Series |
|---|---|---|
| Main Positioning | Balance of power and system compatibility | Maximum power per module |
| Module Width | More conventional format | Larger module format |
| Handling | Relatively easier | Requires more handling planning |
| Typical Projects | C&I and utility projects | Primarily large utility projects |
| Module Count | High-output solution | Potentially fewer modules |
| Logistics | Strong container utilization | Project-specific logistics planning |
| Selection Priority | Compatibility and installation practicality | Maximum wattage and module-count reduction |
Bifacial energy gain is the additional electricity generated by the rear side of a bifacial solar module. It should not be treated as a fixed percentage because actual rear-side generation depends on the installation environment and system design.
Although the module may be capable of achieving additional energy yield under favorable conditions, the final gain can vary significantly from one project to another.
Ground albedo describes the percentage of sunlight reflected by the surface beneath and around the modules. Light-colored and reflective surfaces generally provide more rear-side irradiance than dark surfaces.
White roofing membranes, light-colored concrete, pale gravel, sand, and snow-covered ground can provide relatively favorable reflectivity. Dark soil, vegetation, and asphalt generally reflect less sunlight and may produce a lower bifacial contribution.
Surface reflectivity can also change over time because of dust, vegetation growth, standing water, snow, or changes in ground treatment.
Increasing the distance between the module and the ground or roof surface can improve the distribution of reflected light across the rear side. Very low mounting heights may restrict reflected irradiance and create uneven rear-side illumination.
However, increasing installation height may also affect structural cost, wind loading, maintenance access, and mounting requirements. The final height should therefore be optimized as part of the complete project design.
Module tilt affects both front-side solar exposure and the amount of reflected light that can reach the rear surface. Row spacing also influences rear-side shading, especially during the morning, late afternoon, and winter months.
Rows installed too close together may increase shading on both the front and rear sides. Wider spacing may improve energy yield but requires more land. The most suitable layout depends on latitude, module orientation, land availability, tracking strategy, and the project’s economic objectives.
Mounting rails, tracker torque tubes, cables, cable trays, junction boxes, vegetation, and nearby structures can shade the rear surface. Even when the front side remains unshaded, uneven rear-side shading may reduce bifacial gain.
The mounting and cable-management design should therefore keep the rear surface as open as reasonably possible.
Bifacial performance depends on direct sunlight, diffuse light, and reflected irradiance. Local weather patterns, cloud cover, atmospheric conditions, and seasonal solar angles all affect the available energy.
Dust and dirt can reduce both front-side and rear-side performance. Cleaning frequency should be determined according to rainfall, local pollution, agricultural activity, soil conditions, and accessibility.
The rear-side energy gain is therefore not a fixed value. Project-specific simulation should be used to estimate the expected contribution based on ground reflectivity, installation height, tilt angle, row spacing, structural shading, local irradiance, and long-term surface conditions.
| Cell | N-type TOPCon(132) |
| Dimensions | 2382±2mm×1134±2mm×30±1mm |
| Weight | 34kg±3% |
| Glass | 2.0mm AR coating heatstrenthened glass,low iron |
| Frame | Anodized aluminium alloy |
| junctionbox | IP68,3 diodes |
| Wireway | 4mm²,350mm(+)/350mm(-)or customized length |
| Packaging | 36pieces/pallet |
| Loading quantity | 40HQ:720pieces,17.5 meter truck:828pieces |

| Maxsystem voltage | 1500V DC |
| Operating Temperature | -40C~+85℃ |
| Fuse's rated current | 25A |
| Maxload front | 5400Pa |
| Maxload back | 2400Pa |
| NOCT | 45±2°C |
| Backside rate | 80%±5℃ |
| Safety level | Class ll |
| Fire performance | UL Type l |

| Model | JKL132-D-605NB | JKL132-D-610NB | JKL132-D-615NB | JKL132-D-620NB | JKL132-D-625NB |
| STC/NOCT | STCNOCTSTC | STCNOCTSTC | STCNOCTSTC | STCNOCTSTC | STCNOCTSTC |
| Maximum power [W] | 605454484 | 610458488 | 615461492 | 620465496 | 625470500 |
| Maximum working voltage [V] | 40.5137.9640.49 | 40.7138.1540.69 | 40.9138.3440.89 | 41.1138.5240.96 | 41.3238.7141.17 |
| Maximum working current [A] | 14.9411.9511.94 | 14.9911.9911.98 | 15.0412.0312.02 | 15.0912.0712.04 | 15.1412.1112.09 |
| Open circuit voltage [V] | 48.7246.2848.71 | 48.9246.4748.01 | 49.1246.6649.11 | 49.3246.8549.31 | 49.5347.0649.51 |
| Short circuit current [A] | 15.5212.6612.65 | 15.8712.7112.69 | 15.9212.7412.73 | 15.9712.7812.77 | 16.0212.8412.83 |
| EFF [%] | 22.41% | 22.58% | 22.77% | 22.95% | 23.13% |
| Power tolerance [W] | 0 ~+5W | ||||
| Short circuit current temperature coefficient | +0.046%/℃ | ||||
| Open circuit voltage temperature coefficient | -0.250%/℃ | ||||
| Maximum power temperature coefficient | -0.300%/℃ | ||||
| STC | Irradiance 1000W/m2, Cell temperature 25℃,Spectral AM1.5 | ||||
| NOCT | Irradiance 800W/m2, Ambient temperature20℃, Spectrum AM1.5,Wind speed 1m/s | ||||
Note:The electrical performance parameters in this product catalog do not only refer to a single module, nor are they promised in the contract.
The electrical parameters are only used for comparison between different module types.